DOBD DashX ☰ Browse all codes Blog For business
P2415

O2 Sensor Exhaust Sample Error Bank 2 Sensor 1

Fuel & air metering (emissions) Generic OBD-II Medium

What it means

P2415 means the upstream oxygen sensor on Bank 2 (before the catalytic converter) is not sampling the exhaust correctly — often from a failing sensor, a nearby exhaust leak, or a restricted sample passage. The car usually still drives, but fueling accuracy and emissions monitoring suffer until it is repaired.

Medium

Can I keep driving? Usually drivable — the car may run slightly rich or lean, so fix it soon to keep fueling accurate and pass emissions.

What this part does

The oxygen sensor sits in the exhaust and measures how much unburned oxygen is leaving the engine, which shows whether the air-fuel mixture is rich or lean. The engine control module uses the signal to fine-tune fueling, and sensors after the catalytic converter help check that the converter works. A fault can cause poorer fuel economy, rough running or a check engine light.

Common symptoms

What you'll notice

Read & clear P2415 yourself

Scan your car, confirm the code, and clear it once it's fixed — with OBD DashX on your phone.

▶ Get it on Google Play
Point your phone camera here

Need a scanner that reads ABS, airbag and more? GaragePro OBD scan tools ship worldwide. Claim deal →

Common causes

Most likely first

  1. Failed or contaminated Bank 2 Sensor 1 (upstream) oxygen sensor
  2. Exhaust leak near the upstream sensor letting outside air in
  3. Corroded connector or damaged wiring at the sensor
  4. Restricted or blocked sensor sample/reference passage
  5. Genuine rich or lean condition upstream affecting the sample

Repair

Likely repair

How to diagnose & fix

Work through it in order

  1. Read freeze-frame data and check for related fuel-trim codes.
  2. Inspect the exhaust for leaks near the Bank 2 upstream sensor.
  3. Inspect the sensor connector and wiring for corrosion or damage.
  4. View live O2 data to confirm the sensor is not switching normally.
  5. Replace the Bank 2 Sensor 1 oxygen sensor if faulty, then clear and re-test.

FAQ

Quick answers

Is it safe to drive with P2415?+
Usually yes for short trips, but a bad upstream sensor can skew fueling, so repair it soon to protect economy and emissions.
Can I just clear P2415?+
It returns once the sensor sample fails again unless the sensor, wiring, or exhaust leak is fixed.

Related codes

✓ Verified name — SAE J2012 / ISO 15031-6Guidance reviewed by OBD DashX

About this page

Scan figures come only from diagnostic scans recorded through our own apps and tools. Cars are usually scanned because a symptom or warning light prompted it, so these figures describe our scan records, not how often a fault occurs in any make or model.

Notes about specific manufacturers summarise public records (NHTSA owner complaints, recalls and manufacturer service bulletins), cited under each note. They report what those records say, not our measurements, and they do not suggest that any manufacturer or vehicle is better or worse than another.